Processing
|
Cold rolling, Annealed
|
Standard
|
ASTM B708, ASTM F 560
|
Thickness
|
0.01 mm - 0.5 mm
|
Width
|
20-600mm
|
Length
|
As Your Required
|
Grade
|
RO5200, RO5400
|
Surface
|
No burr No oil spots
|
Shape
|
Foil, in Coil
|
Applications:
Electron-beam melting
Laboratory equipment.
Substitute for platinum.
Manufacturing super alloys
Glass and ceramic industries
Metallurgical
Machinery processing
Quality Assurance:
According to globally recognized standards, such as ASTM, AMS, ASME,JIS,MIL.
Chemical composition, Mechanical properties, making sure no defects inside the products.
ISO Quality Management System.
Packing: Wooden case, plywood case, or according to clients’ demand.
Tantalum can be used as a replacement for platinum for laboratory apparatus which has to have good corrosion resistance. The fluids in the human body do not react with the metal and, it is used for surgical implants without rejection. It is also used as an alloying element with, for example, nickel and molybdenum, to produce alloys which have good corrosion resistance, strength and ductility.
Our staff oversees the production of each Tantalum Foil (Tantalum Strip) to ensure quality and customer satisfaction. This means you get the best selection of Tantalum Foil (Tantalum Strip) at the best price.
Grade: RO5200, RO5400, RO5252(Ta-2.5W), RO5255 (Ta-10W)
Purity: 99.95% min or 99.99% min conformity with ASTM B 708
Specifications:
|
Thickness(mm)
|
Width(mm)
|
Length(mm)
|
Foil
|
0.03-0.07
|
30-200
|
>50
|
Sheet
|
0.07-0.5
|
30-700
|
30-2000
|
Board
|
0.5-10
|
50-1000
|
50-3000
|
Chemistry%
|
Designation
|
Chief Component
|
Impurities Maximum
|
Ta
|
Nb
|
Fe
|
Si
|
Ni
|
W
|
Mo
|
Ti
|
Nb
|
O
|
C
|
H
|
N
|
Ta1
|
Remainder
|
|
0.004
|
0.003
|
0.002
|
0.004
|
0.006
|
0.002
|
0.03
|
0.01
|
0.004
|
0.0015
|
0.002
|
Ta2
|
Remainder
|
|
0.01
|
0.01
|
0.005
|
0.02
|
0.02
|
0.005
|
0.08
|
0.015
|
0.01
|
0.0015
|
0.01
|
TaNb3
|
Remainder
|
<3.5
|
0.01
|
0.01
|
0.005
|
0.02
|
0.02
|
0.005
|
|
0.015
|
0.01
|
0.0015
|
0.01
|
TaNb20
|
Remainder
|
17.0-23.0
|
0.01
|
0.01
|
0.005
|
0.02
|
0.02
|
0.005
|
|
0.015
|
0.01
|
0.0015
|
0.01
|
Ta2.5W
|
Remainder
|
|
0.005
|
0.003
|
0.002
|
3
|
0.006
|
0.002
|
0.04
|
0.015
|
0.005
|
0.0015
|
0.006
|
Ta10W
|
Remainder
|
|
0.005
|
0.003
|
0.002
|
11
|
0.006
|
0.002
|
0.04
|
0.015
|
0.005
|
0.0015
|
0.006
|
Mechanical requirements (Annealed condition):
Grade and size
|
Annealed
|
Tensile strength
|
Yield strength min, Mpa
|
Elongation min, %
|
min, Mpa
|
-2%
|
(1 inch gage length)
|
Sheet, foil and board (RO5200, RO5400) Thickness<0.060‘’(1.524mm)
|
207
|
138
|
20
|
Thickness ≥0.060‘’(1.524mm)
|
172
|
103
|
30
|
Ta-10 W ( RO5255)
|
482
|
414
|
15
|
Sheet, foil and board
|
482
|
379
|
20
|
Ta -2.5W (RO5252) Thickness <0.125”(3.175mm)
|
276
|
207
|
20
|
Thickness ≥0.125”(3.175mm)
|
276
|
152
|
25
|
Ta-40Nb (RO5240) Thickness<0.060"(1.524mm)
|
276
|
138
|
25
|
Thickness>0.060"(1.524mm)
|
241
|
103
|
25
|
Product Name
|
Tantalum foil/sheet
|
Purity
|
99.95%
|
Width
|
5-200mm or customized
|
Technolgy
|
Hot-rolled/Cold-rolled
|
Service
|
7 days omline
|
Application
|
1. Electronic Instrument
|
2. Industry Steel industry
|
3. Chemical industry
|
4. Atomic energy industry
|
5. Aerospace aviation
|
6. Cementedcarbide
|
7. Medical treatment
|
Application:
Tantalum Foil is used in chemical process equipment, cathodic protection systems for steel structures such as bridges, water tanks, prosthetic devices for humans such as hips, plates in the skull, suture clips, corrosion resistant fasteners, screws, nuts, bolts, high temperature furnace parts and high temperature alloys (Ta10W alloy) for air and land based turbines (e.g. jet engines).